How many meters should the lights in the walkway be spaced2020-08-17 09:09:36
How many meters should the lights in the walkway be spaced

Evacuation indicator light is a kind of emergency fire lighting, made of industrial plastic and light bulbs, with two arrows on the sign, often used in factories, hotels and schools and other public places in the corridor, used for emergency blackout lighting.However, many people are not familiar with the installation of evacuation indicators, so how many meters should the evacuation indicators in the aisle be separated?What are the installation specifications for aisle lights?



How many meters should the evacuation lights on the walkway be separated:


Normally, the distance between the evacuation indicator lights in the aisle should not be more than 20 meters. It should be placed in a prominent position at the safety exit, such as the wall at the corridor and corner, and the distance from the ground should be less than 1 meter.If the wall cannot be hung, the lower mouth can be lifted, but the distance from the ground should not be more than 2.4 meters.Specific details can refer to the civil electrical design code.


What are the installation specifications for aisle lights:


The evacuation indicator light shall be equipped with normal power supply and emergency power supply, in which the emergency power supply can be provided by the self-provided power generation or battery supply. If it is a battery, the battery shall be continuously charged for more than 3 hours.


When the aisle indicator is installed, in order to fully illuminate the aisle and evacuation route, the luminance should not be lower than 0.5Lx, especially for some fire water pump rooms and dangerous places prone to fire, the lighting brightness of the indicator should be ensured.



 Evacuation indicator light is recommended to be placed in an obvious position to facilitate people to evacuate more quickly, such as on the wall of the door roof or corridor, but the distance from the ground shall not be more than 1 meter, and the distance between the two adjacent indicators shall not be more than 20 meters.